MultiModemDID User Guide | Chapter 4 - AT Commands, |
|
|
Subparameters |
|
direction | Specifies the DTE direction of the data compression. |
0 | No compression. |
3 | Compression in both directions (default). |
max_codewords_tx | Specifies the maximum number of code words to be negotiated |
| in the transmit direction. |
1024 | Default. |
Maximum number of code words in transmit direction. | |
max_codewords_rx | Specifies the maximum number of code words to be negotiated |
| in the receive direction. |
1024 | Default. |
Maximum number of code words in receive direction. | |
max_string_tx | Specifies the maximum string length to be negotiated in the |
| transmit direction. |
255 | Default. |
max_string_rx | Specifies the maximum string length to be negotiated in the |
| receive direction. |
255 | Default. |
max_history_tx | Specifies the maximum length of the history buffer to be |
| negotiated in the transmit direction. |
5120 | Default. |
History buffer size in transmit direction. | |
max_history_rx | Specifies the maximum length of the history buffer to be |
| negotiated in the receive direction. |
4096 | Default. |
History buffer size in receive direction. | |
Command: +ES=n | Enable Synchronous Buffered Mode |
Values: | n = 6 |
Default: | None |
Description: | Allows an H.324 video application direct access to the |
| synchronous data channel. On underflow, the modem sends |
| HDLC flag idle (0x7E) to the remote modem. This special error |
| control mode is overridden by any of the following commands: |
| &F, &M, &Q, or \N. |
+ES=6 | Enables direct access to the synchronous data channel. |
+ES=? Displays the allowed values. | |
+ES? | Displays the current value. |
25