MultiModemDID User Guide

Chapter 4 - AT Commands, S-Registers, Result Codes

 

 

 

 

17

48000 bps

 

18

49333 bps

 

19

50666 bps

 

20

52000 bps

 

21

53333 bps

 

22

54666 bps

 

23

56000 bps

S42

decimal

0–1

1

Enables/disables the 56K auto rate. When

 

 

 

 

56K auto is disabled, fallback to V.34 is also

 

 

 

 

disabled. 0 = disable; 1 = enable.

S48

decimal

7 or 128

7

Enables (7) or disables (128) LAPM

 

 

 

 

negotiation. The following table lists the S36

 

 

 

 

and S48 configuration settings for certain

 

 

 

 

types of connections.

 

 

 

 

 

 

 

 

 

 

 

 

 

S48=7

S48=128

 

 

 

 

 

 

 

 

 

 

 

S36=0, 2

LAPM or hangup

Do not use

 

 

 

 

 

 

 

 

 

 

 

S36=1, 3

LAPM or async

Async

 

 

 

 

 

 

 

 

 

 

 

S36=4, 6

LAPM, MNP, or hangup

MNP or hangup

 

 

 

 

 

 

 

 

 

 

 

S36=5, 7

LAPM, MNP, or aysnc

MNP or async

S89

 

 

 

 

 

 

seconds

0, 5–255

0

Sets the length of time in the off-line

 

 

 

 

command mode before the modem goes

 

 

 

 

into standby mode. A value of zero prevents

 

 

 

 

standby mode; a value of 1–4 sets the value

 

 

 

 

to 5.

 

 

S108

decimal

0–3, 6, 7

6

Selects the 56K digital loss if using the

 

 

 

 

modem thru a PBX line. The default value is

 

 

 

 

-6 dB loss, the value used when calling from

 

 

 

 

a typical POTS line long distance.

 

 

 

 

Value

Digital loss

 

 

 

 

 

0

-0 dB digital loss, no robbed-bit

 

 

 

 

 

signaling

 

 

 

 

 

1

-3 dB PBX digital loss

 

 

 

 

2

-2 dB digital loss

 

 

 

 

 

3

-3 dB digital loss

 

 

 

 

 

6

-6 dB digital loss

 

 

 

 

 

7

-0 dB digital loss with robbed-bit

 

 

 

 

 

signaling

 

38