6 Callback Security

5.After the delay specified by the #CBDn command, the callback mo- dem calls the extension that you entered after the + character. If the callback modem is unable to establish a connection, it tries again, up to the number of attempts specified by the #CBAn command.

6.After the modems reconnect, the following message reappears:

Password>

7.Type the same password that you used to initiate the call. You have three attempts to enter the password or be disconnected.

8.If the password is valid, the following message appears and the modems establish a working connection:

OK Connecting

Direct Connection

Use this procedure when you want to connect without first being called back. The password that you use must be set up for an optional direct connection.

1.Using a data communications program such as HyperTerminal, dial the number of the callback modem..

2.When the connection is established, the callback modem responds with the following message:

Password>

3.Type a direct connection password, press the - key, and press EN- TER You have three attempts or one minute to enter a valid pass- word.

4.If the password is valid, the following message appears and the modems establish a working connection:

OK Connecting

93

Page 103
Image 103