User Guide

Command: #Sx

Enter Setup Password

Values:

x= password (1–8 characters, case sensitive)

Default:

MTSMODEM

Description:

Enters the password used for callback security

 

and remote configuration setup. This command

 

allows the use of all callback security commands.

Command: #S=x Store Setup Password

Values:

x= password (1–8 characters, case sensitive)

Default:

MTSMODEM

Description:

Stores a new password for callback security and

 

remote configuration setup.

Command:

&V

Display Current Settings

Values:

 

n/a

Description:

 

Displays the modem’s active settings, including

 

 

the telephone numbers stored in nonvolatile

 

 

memory and the security settings, if enabled. If

 

 

the setup password has been entered, the pass-

 

 

words are also displayed.

Command:

&Zy=[+][-]x[,???]Store Dialing Command

Values:

 

y = 0–29 (callback security enabled)

 

 

x = Dialing command string

Default:

 

None

Description:

 

Stores dialing command x in memory location y.

 

 

The command string must begin with AT and can

 

 

have up to 35 characters. The telephone number

 

 

in the command must be preceded by D, DT, or

DP. Example: AT&Z0=+-ATM0D5551212,???. During a call, if the + or - character is not entered after the password, the modem will call back the stored number. This command can be entered

98

Page 108
Image 108
Multi-Tech Systems MT5634ZBAV manual Enter Setup Password, Zy=+-x,???Store Dialing Command