Multi-Tech Systems MT5634ZBAV manual Register Unit Range, S48, S89, S108

Models: MT5634ZBA MT5634ZBAV

1 170
Download 170 pages 6.29 Kb
Page 84
Image 84

User Guide

Register

Unit

Range

 

Default

Description

S48

decimal

7 or 128

7

Enables (7) or disables (128)

 

 

 

 

 

 

LAPM negotiation. The fol-

 

 

 

 

 

 

lowing table lists the S36 and

 

 

 

 

 

 

S48 configuration settings for

 

 

 

 

 

 

certain types of connections.

 

 

 

 

 

 

 

 

 

 

 

 

S48=7

S48=128

 

 

 

 

 

 

 

S36=0, 2

LAPM or hangup

Do not use

 

 

 

 

 

 

 

S36=1, 3

LAPM or async

Async

 

 

 

 

 

 

 

S36=4, 6

LAPM, MNP, or hangup

MNP or hangup

 

 

 

 

 

 

 

S36=5, 7

LAPM, MNP, or aysnc

MNP or async

S89

 

 

 

 

 

 

seconds

0, 5–255 10

Sets the length of time in the

 

 

 

 

 

 

off-line command mode be-

 

 

 

 

 

 

fore the modem goes into

 

 

 

 

 

 

standby mode. A value of

 

 

 

 

 

 

zero prevents standby mode;

 

 

 

 

 

 

a value of 1–4 sets the value

 

 

 

 

 

 

to 5.

 

S108

decimal

0–3, 6, 7

6

Selects the 56K digital loss if

 

 

 

 

 

 

using the modem thru a PBX

 

 

 

 

 

 

line. The default value is -6

 

 

 

 

 

 

dB loss, the value used when

 

 

 

 

 

 

calling from a typical POTS

 

 

 

 

 

 

line long distance.

0 = -0 dB digital loss, no robbed-bit signaling

1 = -3 dB PBX digital loss

2 = -2 dB digital loss

3 = -3 dB digital loss

6 = -6 dB digital loss

7 = -0 dB digital loss with robbed-bit signaling

74

Page 84
Image 84
Multi-Tech Systems MT5634ZBAV manual Register Unit Range, S48, S89, S108