120V Hard Wire Hookup

DCA-15SPX3 — OUTPUTTERMINAL INFORMATION

120V Hard Wire Hookup

The output terminal panel, when suppling single phase 120 volts, will provide two circuits available at 62.5 amps with any two wires plus the ground. (See Figure 10 below.)

240V Hard Wire Hookup

The output terminal panel, when suppling single phase 240 volts, will provide one circuit available at 62.5 amps with two wires plus the ground. (See Figure 11 below.)

Figure 10. Hard Wire Hookup

Figure 11. Hard Wire Hookup

for 120 Volt

for 240 Volt

NOTE

When using plural single phase voltages, make sure to balance the load on each of the single phase legs.

PAGE 28 — DCA-15SPX3 GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (09/03/01)