CAUTION :

When adding coolant or antifreeze to the radiator, do not remove the radiator cap until the unit has completely cooled.

Day-to-day addition of coolant is done from the reserve tank. When adding coolant to the radiator, DO NOT remove the radiator cap until the unit has completely cooled. See Table

8.for engine, radiator, and reserve tank coolant capacities. Make sure the coolant level in the reserve tank is always between the "H" and the "L" markings.

Table 8. Coolant Capacity

Engine and Radiator

1.11 Gal. (4.2L)

 

 

Reserve Tank

0.26 Gal. (1L)

 

 

Operation in Freezing Weather

When operating in freezing weather, be certain the proper amount of antifreeze (Table 9) has been added.

Table 9. Anti-Freeze Operating Temperatures

Vol %

Freezing Point

Boiling Point

 

 

 

 

Anti-Freeze

°C

°F

°C

°F

 

 

 

 

 

 

40

-24

-12

106

222

 

 

 

 

 

50

-37

-34

108

226

 

 

 

 

 

NOTE

When the antifreeze is mixed with water, the antifreeze mixing ratio must be less than 50%.

DCA-15SPX3PRE-SETUP

Cleaning the Outer Radiator

The engine may overheat if the radiator fins become overloaded with dust or debris. Periodically clean the radiator fins with compressed air. Cleaning inside the radiator is dangerous, so clean only with the engine turned off and the battery disconnected.

Air Cleaner

Periodic cleaning/replacement is necessary. Inspect it in accordance with the Kubota Engine Owner's Manual.

Fan Belt Tension

A slack fan belt may contribute to overheating, or to insufficient charging of the battery. Inspect the fan belt for damage and wear and adjust it in accordance with the Kubota Engine Owner's Manual.

The fan belt tension is proper if the fan belt bends 10 to 15

mm(Figure 14) when depressed with the thumb as shown below. Never place hands near the belts or fan while the generator is running.

Figure 14. Fan Belt Tension

CAUTION :

Never place hands near the belts or fan while the generator set is running.

Adjusting Fan Belt

If the fan belt does not have the 10 to 15mm defection follow the procedure below to adjust:

Loosen the alternator adjusting plate and alternator mounding bolt.

Pivot the alternator at the mounting bolt toward the engine left or right until the belt reflects the proper tension. Tighten the mounting bolt and the adjusting bolt.

PAGE 34 — DCA-15SPX3 GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (09/03/01)

Page 34
Image 34
Multiquip DCA-15SPX3 Operation in Freezing Weather, Cleaning the Outer Radiator, Air Cleaner Fan Belt Tension

DCA-15SPX3 specifications

The Multiquip DCA-15SPX3 is a versatile and robust generator designed for a range of applications, making it an ideal choice for contractors, events, and emergency power needs. With a powerful output of 15 kW, this generator is equipped to handle a variety of electrical loads, providing reliable, consistent power.

One of the standout features of the DCA-15SPX3 is its impressive fuel efficiency, thanks to a quiet-running and high-performance engine. This model is designed with a durable, weather-resistant enclosure that not only protects the generator from harsh environmental conditions but also reduces noise levels, making it suitable for use in residential areas or during events where noise control is essential.

The generator operates on diesel fuel, which is known for its efficiency and longevity compared to gasoline-powered counterparts. The DCA-15SPX3 has a user-friendly control panel, offering easy accessibility to start and stop operations. Additionally, it includes built-in safety features, such as low oil shutdown and overload protection, ensuring that the generator operates safely and efficiently.

The DCA-15SPX3 also incorporates advanced technology like digital automatic voltage regulation (AVR), which provides stable voltage output and reduces the likelihood of damage to sensitive electronics and equipment. This technology ensures that the generator maintains a consistent power supply even as the load varies, enhancing its suitability for both light commercial and heavy industrial applications.

With a compact design, the generator is easy to transport and set up, making it convenient for on-the-go power solutions. It features built-in lifting hooks and is mounted on a robust chassis for better mobility. The unit’s low maintenance requirements further enhance its appeal, allowing users to focus more on their tasks rather than routine upkeep.

Overall, the Multiquip DCA-15SPX3 stands out in the market for its balance of power, efficiency, and ease of use, making it an invaluable asset for professionals requiring dependable power in diverse settings. Whether used for temporary job sites, special events, or as a backup power source, it delivers the performance and reliability expected from a high-quality generator.