DCA-15SPX3 — GENERATOR START-UP PROCEDURE

WARNING:

The engine's exhaust contains harmful

2. Connect the load to the UNV terminals as shown in

emissions. ALWAYS ventilate the

Figure 17. These terminals can be found on the front of

exhaust when operating inside tunnels,

the generator by lifting the UNV lug cover. It may be

excavations or buildings. Direct exhaust

necessary to remove the retaining lug that secures the

away from nearby personnel.

cover. Make sure to tighten terminal nuts securely to

 

prevent load wires from slipping out.

Before Starting

Engine

1.Check the lubricating oil level prior to starting the engine. Make sure the generator is level. The oil level must be maintained between two notches on the dipstick.

2.When there is not enough lubricating oil, fill the crankcase with high grade motor oil. Use a high quality detergent oil classified CC or higher (See Table 7 on page 29).

3.Check the coolant level in the radiator and subtank. Replenish with antifreeze as necessary. Always maintain the coolant level between the FULL and LOW markings on the coolant container. Be sure that the radiator cap is fastened securely.

4.Check the fuel level on the fuel gauge. If fuel is low, fill the fuel tank with clean fresh unleaded automotive diesel fuel. If fuel spillage occurs, clean immediately.

Figure 17. UNV Terminal Lugs (Load)

3.After attaching the load wires to the AC output terminals, secure the UNV cover by inserting the retaining screw (Figure 18) back into the cover.

Before Starting

Generator and Control Panel

CAUTION:

NEVER start the engine with the main or GFCI circuit breakers in the ON position.

1. Be sure to disconnect the electrical load and switch the

Figure 18. UNV Lug Cover

main and G.F.C.I. circuit breakers (Figure 16) to the

 

“OFF” position prior to starting the engine.

 

CIRCUIT BREAKER

CIRCUIT BREAKER

 

MAIN

GFCI RECEPTACLE

 

OFF OFF

Figure 16. Main and GFCI Circuit Breakers

DCA-15SPX3 GENERATOR — PARTS & OPERATION MANUAL — REV. #2 (09/03/01) — PAGE 37

Page 37
Image 37
Multiquip DCA-15SPX3 operation manual Before Starting Engine, Before Starting Generator and Control Panel

DCA-15SPX3 specifications

The Multiquip DCA-15SPX3 is a versatile and robust generator designed for a range of applications, making it an ideal choice for contractors, events, and emergency power needs. With a powerful output of 15 kW, this generator is equipped to handle a variety of electrical loads, providing reliable, consistent power.

One of the standout features of the DCA-15SPX3 is its impressive fuel efficiency, thanks to a quiet-running and high-performance engine. This model is designed with a durable, weather-resistant enclosure that not only protects the generator from harsh environmental conditions but also reduces noise levels, making it suitable for use in residential areas or during events where noise control is essential.

The generator operates on diesel fuel, which is known for its efficiency and longevity compared to gasoline-powered counterparts. The DCA-15SPX3 has a user-friendly control panel, offering easy accessibility to start and stop operations. Additionally, it includes built-in safety features, such as low oil shutdown and overload protection, ensuring that the generator operates safely and efficiently.

The DCA-15SPX3 also incorporates advanced technology like digital automatic voltage regulation (AVR), which provides stable voltage output and reduces the likelihood of damage to sensitive electronics and equipment. This technology ensures that the generator maintains a consistent power supply even as the load varies, enhancing its suitability for both light commercial and heavy industrial applications.

With a compact design, the generator is easy to transport and set up, making it convenient for on-the-go power solutions. It features built-in lifting hooks and is mounted on a robust chassis for better mobility. The unit’s low maintenance requirements further enhance its appeal, allowing users to focus more on their tasks rather than routine upkeep.

Overall, the Multiquip DCA-15SPX3 stands out in the market for its balance of power, efficiency, and ease of use, making it an invaluable asset for professionals requiring dependable power in diverse settings. Whether used for temporary job sites, special events, or as a backup power source, it delivers the performance and reliability expected from a high-quality generator.