CAUTION:

Battery

Never over fill the battery with water above the upper limit.

The battery has acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

1.DO NOT drop the battery. There is the possibility of risk the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged, a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in

contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

RULES FOR SAFE OPERATION

NEVER Run engine without air filter. Severe engine damage may occur.

Always service air cleaner frequently to prevent carburetor malfunction.

Always disconnect the battery before performing service on the generator.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Always store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT leave the generator running in the manual mode unattended.

DO NOT allow unauthorized people to operate this equipment.

Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Refer to the Kubota Engine Owner's Manual for engine technical questions or information.

Loading and Unloading (Crane)

Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

Always drain fuel prior to lifting.

Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

NEVER lift the machine while the engine is running.

Use adequate lifting cable (wire or rope) of sufficient strength.

When lifting the generator, always use the balanced center- point suspension hook and lift straight upwards.

NEVER allow any person or animal to stand underneath the machine while lifting.

When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 — DCA-15SPX3 GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (09/03/01)

Page 8
Image 8
Multiquip DCA-15SPX3 operation manual Battery, Loading and Unloading Crane

DCA-15SPX3 specifications

The Multiquip DCA-15SPX3 is a versatile and robust generator designed for a range of applications, making it an ideal choice for contractors, events, and emergency power needs. With a powerful output of 15 kW, this generator is equipped to handle a variety of electrical loads, providing reliable, consistent power.

One of the standout features of the DCA-15SPX3 is its impressive fuel efficiency, thanks to a quiet-running and high-performance engine. This model is designed with a durable, weather-resistant enclosure that not only protects the generator from harsh environmental conditions but also reduces noise levels, making it suitable for use in residential areas or during events where noise control is essential.

The generator operates on diesel fuel, which is known for its efficiency and longevity compared to gasoline-powered counterparts. The DCA-15SPX3 has a user-friendly control panel, offering easy accessibility to start and stop operations. Additionally, it includes built-in safety features, such as low oil shutdown and overload protection, ensuring that the generator operates safely and efficiently.

The DCA-15SPX3 also incorporates advanced technology like digital automatic voltage regulation (AVR), which provides stable voltage output and reduces the likelihood of damage to sensitive electronics and equipment. This technology ensures that the generator maintains a consistent power supply even as the load varies, enhancing its suitability for both light commercial and heavy industrial applications.

With a compact design, the generator is easy to transport and set up, making it convenient for on-the-go power solutions. It features built-in lifting hooks and is mounted on a robust chassis for better mobility. The unit’s low maintenance requirements further enhance its appeal, allowing users to focus more on their tasks rather than routine upkeep.

Overall, the Multiquip DCA-15SPX3 stands out in the market for its balance of power, efficiency, and ease of use, making it an invaluable asset for professionals requiring dependable power in diverse settings. Whether used for temporary job sites, special events, or as a backup power source, it delivers the performance and reliability expected from a high-quality generator.