DCA-25SSI — SPECIFICATIONS

 

 

 

 

 

 

 

 

 

 

 

 

Table 5. Specifications

 

 

 

 

 

 

 

 

Generator Specifications

 

 

 

 

 

 

 

 

Model

 

DCA-25SSI

 

 

 

 

 

 

 

Type

Revolving field, self ventilated, open protected type synchronous

 

 

 

 

 

 

 

 

Armature Connection

Star with Neutral

 

Zig Zag

 

 

 

 

 

 

 

 

Phase

3

 

Single

 

 

 

 

 

 

 

 

Standby Output

26.5 KVA (21.2 KW)

 

15.3KW

 

 

 

 

 

 

 

 

Prime Output

25 KVA (20 KW)

 

14.4KW

 

 

 

 

 

 

 

 

Voltage

240V or 480V

 

240/120V

 

 

 

 

 

 

 

 

Frequency

 

 

60 Hz

 

 

 

 

 

 

 

 

Speed

 

1800 rpm

 

 

 

 

 

 

 

 

Power Factor

0.8

 

1

 

 

 

 

 

 

 

Aux. AC Power

Single Phase, 60 Hz

 

 

 

 

 

 

 

 

Voltage

 

 

120 V

 

 

 

 

 

 

 

Output

7.2 KW (3.6 KW x 2)

 

 

 

 

 

 

 

 

Engine Specifications

 

 

 

 

 

 

 

Model

Isuzu QD-60(C240)

 

 

 

 

 

 

 

Type

4 Cycle, water-cooled, swirl combustion chamber

 

 

 

 

 

 

 

 

No. of Cylinders

 

4 cylinders

 

 

 

 

 

 

 

Bore x Stroke

3.38 in. x 4 in. (86 mm x 102 mm)

 

 

 

 

 

 

 

Rated Output

30.6HP/1800 rpm

 

 

 

 

 

 

 

Displacement

144 cu. in. (2369cc)

 

 

 

 

 

 

 

 

Starting

 

Electric

 

 

 

 

 

 

 

Coolant Capacity

2.9 gal. (11 liters)

 

 

 

 

 

 

 

Lube Oil Capacity

1.45 gal. (5.5 liters)

 

 

 

 

 

 

 

 

Fuel Consumption

1.65 gal. (6.3L)/hr at full load

 

1.3 gal. (5.0L)/hr at 3/4 load

 

 

 

 

 

 

 

0.9 gal. (3.4L)/hr at 1/2 load

 

0.6 gal. (2.3L)/hr at 1/4 load

 

 

 

 

 

 

 

 

 

 

 

 

Battery

 

12V- 70AH

 

 

 

 

 

 

 

Fuel

#2 Diesel Fuel

 

 

 

 

 

 

 

PAGE 19 — DCA-25SSI — PARTS AND OPERATION MANUAL—FINAL COPY(06/29/01)