DCA-25SSI — GENERAL INFORMATION
DCA-25SSI FAMILIARIZATION
Generator
The MQ Power Model
Engine Operating Panel
The “Engine Operating Panel” is provided with the following:
zTachometer
zWater Temperature Gauge
zOil Pressure Gauge
zCharging Ammeter Gauge
zFuel level gauge
zEngine Throttle Lever
z
zAlarm Lights
zPanel Light
zPanel Light Switch
zStarter Switch
Generator Control Panel
The “Generator Control Panel” is provided with the following:
zOutput Voltage Adjustment Knob
zFrequency Meter (Hz)
zAC Ammeter (Amps)
zAC Voltmeter (Volts)
zAmmeter
zVoltmeter
Output Terminal Panel
The “Output Terminal Panel” is provided with the following:
zThree 120/240V output receptacles, 50 amp
zTwo 120V input receptacles, 20 amp
z3 Load Circuit Breakers 240V @50 amps
z2 Load GFCI Circuit Breakers 120V@ 20amps
Control Box
The “Control Box” is provided with the following:
zMain Circuit Breaker 60 amps
z
Open Delta Excitation System
The
There are four leads: A, B, C and D. During light loads, the power to the Automatic Voltage Regulator (AVR) is supplied from the leads parallel connections of B&C. When loads increase, the AVR switches and accepts power from leads A&D. The output of leads A&D increase proportionally with load. This of adding the voltages to each phase provides better voltage response during heavy loads.
The connections of the AVR to the AC output windings are for sensing only. No power is required from these windings.
The
Engine
The
In keeping with MQ Power’s policy of constantly improving its products, the specifications quoted herein are subject to change without prior notice.
The basic controls and indicators for the
Mechanical Governor System
The mechanical governor system control the RPM of the engine. When the engine demands increase or decrease, the mechanical governor system regulates the frequency variation to ±1.5%. The electronic governor option in- creases frequency variation to ±.25%.
PAGE 20 —