Battery

CAUTION:

Never over fill the battery with water above the upper limit.

The battery has acids that can cause injury to the eyes and skin. To avoid eye irritation, always wear safety glasses. Use well insulated gloves when picking up the battery. Use the following guidelines when handling the battery:

RULES FOR SAFE OPERATION

NEVER Run engine without air filter. Severe engine damage may occur.

Always service air cleaner frequently to prevent carburetor malfunction.

Always disconnect the battery before performing service on the generator.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Always store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children.

DO NOT leave the generator running in the manual mode unattended.

DO NOT allow unauthorized people to operate this equipment.

Always read, understand, and follow procedures in Operator’s Manual before attempting to operate equipment.

Always be sure the operator is familiar with proper safety precautions and operations techniques before using generator.

Refer to the Kubota Engine Owner's Manual for engine technical questions or information.

1.DO NOT drop the battery. There is the possibility of risk the battery may explode.

2.DO NOT expose the battery to open flames, sparks, cigarettes etc. The battery contains combustible gases and liquids. If these gases and liquids come in contact with a flame or spark, an explosion could occur.

3.Always keep the battery charged. If the battery is not charged, a buildup of combustible gas will occur.

4.Always keep battery charging and booster cables in good working condition. Repair or replace all worn cables.

5.Always recharge the battery in an open air environment, to avoid risk of a dangerous concentration of combustible gases.

6.In case the battery liquid (dilute sulfuric acid) comes in contact with clothing or skin, rinse skin or clothing immediately with plenty of water.

7.In case the battery liquid (dilute sulfuric acid) comes in

contact with your eyes, rinse eyes immediately with plenty of water, then contact the nearest doctor or hospital, and seek medical attention.

Loading and Unloading (Crane)

Before lifting, make sure the generator's lifting hook is secure and that there is no apparent damage to the generator itself (loose screws, nuts and bolts). If any part is loose or damaged, please take corrective action before lifting.

Always drain fuel prior to lifting.

Always make sure crane or lifting device has been properly secured to the hook of guard frame on generator.

NEVER lift the machine while the engine is running.

Use adequate lifting cable (wire or rope) of sufficient strength.

When lifting the generator, always use the balanced center- point suspension hook and lift straight upwards.

NEVER allow any person or animal to stand underneath the machine while lifting.

When loading the generator on a truck, be sure to use the front and back frame bars as a means to secure the generator during transport.

PAGE 8 — DCA-10SPX3 A.C. GENERATOR— PARTS & OPERATION MANUAL — REV. #2 (01/17/11)

Page 8
Image 8
Multiquip DCA10SPX3 manual Battery, Loading and Unloading Crane

DCA10SPX3 specifications

The Multiquip DCA10SPX3 is a versatile and robust diesel generator designed to meet the power requirements of various applications. Known for its reliability and efficiency, this generator is particularly well-suited for construction sites, outdoor events, and any situation where a dependable power source is necessary.

One of the standout features of the DCA10SPX3 is its impressive power output. With a maximum output of 10 kW, this generator can support a wide array of electrical equipment, making it ideal for both residential and commercial usage. The generator operates quietly, ensuring that it won't disturb the surrounding environment, which is particularly important for events or near residential areas.

The DCA10SPX3 utilizes a rugged, industrial-grade diesel engine that is designed for durability and low maintenance. This not only enhances the longevity of the generator but also ensures that it can handle tough working conditions. The generator is equipped with a heavy-duty steel frame, providing added protection and stability, further extending its lifespan.

Another significant feature of the DCA10SPX3 is its fuel efficiency. The generator can provide extended runtimes on a single tank of diesel fuel, reducing the frequency of refueling and allowing for longer operational periods. This efficiency is an essential feature for users who need consistent power over extended durations.

The unit is also equipped with advanced technologies for safety and performance. Features such as low oil pressure shutdown, high coolant temperature shutdown, and overload protection help to safeguard the engine and extend service intervals. These technologies ensure that the generator operates within optimal parameters, reducing the risk of unexpected breakdowns.

User-friendly controls make the DCA10SPX3 accessible to operators of all skill levels. The generator includes a digital control panel that displays key metrics such as voltage, frequency, and total runtime. This allows users to monitor performance and make adjustments as necessary easily.

Additionally, the compact design of the DCA10SPX3 facilitates easy transport and maneuverability, making it a practical option for job sites and temporary installations. With its combination of power, durability, and user-friendly features, the Multiquip DCA10SPX3 proves to be an excellent choice for anyone needing reliable and efficient diesel power.