COLD WEATHER OPERATION/POINTER ADJUSTMENT

COLDWEATHER OPERATION

Block Heaters

CAUTION — Block Heaters

DO NOT leave optional block heaters plugged in for extended periods when temperatures may rise above 20oF, (-6.67oCelsius). The oil could “cook” inside the crankcase and damage the engine.

If the water system is not drained when the saw is not in use and temperatures fall below 32o F (0o C), damage may occur to optional water pumps.

Inextremecoldweather,optionalblockheatersmaybeused.Block heaters are installed directly onto the crankcase and are operated by plugging into a 110VAC electrical outlet. Be sure to use appropriate gauge wire when using extension cords and abide by all safety rules when using electical power, power cords, and extension cords. Do not use block heaters when the when temperatures are above 20o F (-6.67oCelsius).

Draining the Water System

When low temperatures fall below 32o F (0o C):

1.If the saw is equipped with an optional water pump, open the drain petcock on the pump and allow the pump to drain.Turn the water pump switch on for a few seconds to purge any water remaining inside the pump body.

2. Tilt the saw UP and BACK, to allow water to drain.

3.Tilt the saw FORWARD, to allow water to drain again.

4.If an air compressor is available, blow out the system by applying compressed air to the water inlet.

POINTER ADJUSTMENT

1.Lower the front pointer assembly (Figure 25).

2.Using 10-12 ft. (3-3.7 meters) of stringline, divide the length of the string in half and slide the string into one of the slots or gullets on the backside of the blade (as viewed standing in front of the pointer) SeeFigure 26, Item 2. Hold both ends of the string in one hand and pull the string taut (Item 3). Move your hand from side to side until both strings are touching both sides of the blade.

3. Adjust the pointer rod (Item 5) by loosening the lock knob (Item 4). Move the pointer directly over the middle of the two strings in your hand and tighten the pointer setscrew

to lock the pointer in position. Repeat this process for the rear pointer.

4.To raise the front pointer assembly (Item 1), first pull back and up on the pointer cable. Secure the pointer assembly in the desired raised position by locking the cable between the jaws of the cam cleat.

Figure 25. Pointer Assembly

2

1

5

4

Top View

3

Figure 26. Adjusting the Pointer Assembly

SP7060 PAVEMENT SAW • OPERATION MANUAL — REV. #0 (02/13/09) — PAGE 33

Page 33
Image 33
Multiquip SP706030 Cold Weather OPERATION/POINTER Adjustment, Coldweather Operation, Block Heaters, Pointer Adjustment

SP706016, SP706026, SP706030, SP706036, SP706020 specifications

Multiquip is a prominent name in the construction equipment industry, known for its innovative and reliable products. Among its versatile offerings, the Multiquip SP706020, SP706016, SP706036, SP706030, and SP706026 stand out as notable concrete pump models. These pumps provide exceptional performance and efficiency, making them ideal for a wide range of applications.

Each model in this lineup is engineered for maximum durability and reliability. The SP706020, for instance, features a powerful and efficient hydraulic system that allows for smooth operation and consistent performance, even in demanding conditions. It is designed with a robust frame that can withstand rigorous job site environments, ensuring longevity and reduced maintenance.

The SP706016 stands out with its compact design, making it suitable for smaller job sites while still offering high output and efficiency. This model is equipped with advanced safety features, such as emergency stop buttons and pressure relief valves, ensuring safe operation for the user and surrounding personnel.

Notably, the SP706036 is designed for high-capacity pumping. It is ideal for larger projects that require higher output without compromising on efficiency. Its advanced pumping technology reduces the potential for blockages, enhancing overall productivity. The SP706030 presents a balance between power and size, making it an excellent choice for medium-scale projects.

The SP706026 is notable for its energy-efficient design, which minimizes fuel consumption while providing robust performance. This model reflects Multiquip's commitment to sustainability and cost-effectiveness, allowing contractors to save on operational costs over time.

Across the series, user-friendly controls and adjustable settings provide operators with the flexibility needed to handle various types of concrete mixes and job specifications. Additionally, these models are fitted with high-quality components that enhance performance and reduce wear and tear.

In summary, the Multiquip SP706020, SP706016, SP706036, SP706030, and SP706026 are versatile concrete pumps equipped with cutting-edge technology, ensuring high efficiency, reliability, and safety on any job site. Their various features and specifications make them a valuable addition to any construction operation, catering to diverse project needs while ensuring exceptional performance.