19
KEYPAD FUNCTIONS
Activate Chime? "MONITOR ON" will be displayed and the Chime Mode will sound a tone
at the keypad when the programmed zone is opened while disarmed. To deactivate the
Chime Mode, execute the "TurnOff Chime" function.
Note: The Chime Mode is disabled while armed.
Activate Watch Mode? (Watch Mode programmed? YES NO). This optional feature
simultaneously turns on all zones designated as Day Zones. When activated, “MONITOR
ON” will display at the keypad. To deactivate the Watch Mode, arm, then disarm. All Day
Zones will revert to regular Burglary Zones. Note: The Watch Mode is disabled while
armed.
Reset System Trouble? System troubles display and sound at the keypad. Correcting
the trouble will clear most indications, however the following error codes will require manual
reset: E11; E13; E19; E20 and E22. (See SYSTEM TROUBLE ERROR CODES for a de-
scription of error codes).
Start Exit Time? (OPTIONAL) (Start Exit Time programmed? YES NO). In Com-
mercial Burglary systems, exit delay may have been programmed to start after a central-
station “ringback” (verification) signal has been received. If the ringback tone has not been
received within about 30 seconds after arming, a communication problem may exist. Use
the “START EXIT TIME” Function to start exit delay manually, then exit the premises imme-
diately. Be sure to have your alarm specialist check communications with the central station
as soon as possible.
Activate Telephone Test? (OPTIONAL) (Telephone Test programmed? YES NO).
Sends a communicator test to the central station. A communication failure will be indicated
at the keypad by an “E03-00 COMMFL” display. Repeat the test to attempt to correct a com-
munication failure, as any successful communication will clear this display.
AC ON
TurnOn/Chime
Yes/No
AC ON
TurnOn/Watch
Yes/No
TROUBLE
AC ON
Reset/SysTbl/
Yes/No
AC ON
Start/ExitTm/
Yes/No
AC ON
TurnOn/TelTst/
Yes/No