Chapter 12 Synchronization
NI-Motion User Manual 12-32 ni.com
CheckError;
return;// Exit the Application
///////////////////////////////////////////////////
//////////////
// Error Handling
//
nimcHandleError; //NIMCCATCHTHIS:
// Check to see if there were any Modal Errors
if (csr & NIMC_MODAL_ERROR_MSG){
do{
//Get the command ID, resource ID, and the
error code of the //modal error from the
error stack on the device
err = flex_read_error_msg_rtn(boardID,
&commandID, &resourceID, &errorCode);
nimcDisplayError(errorCode,commandID,res
ourceID);
//Read the communication status register
err = flex_read_csr_rtn(boardID,&csr);
}while(csr & NIMC_MODAL_ERROR_MSG);
}
else// Display regular error
nimcDisplayError(err,0,0);
return;// Exit the Application
}
Non-Buffered High-Speed Capture