Ventilation Requirements

NCR RealScan 7882 Installation and Owner Guide

Ventilation Requirements

The RealScan 7882 Scanner/Scale is designed to operate without an exhaust fan in the checkstand; however, there must be adequate convection air flow. The ambient temperature inside the checkstand cannot be higher than 104° F (40° C). Also, the ambient temperature inside the checkstand cannot be higher than 12.6° F (7° C) above the ambient temperature outside the checkstand. For example, if the ambient temperature outside the checkstand is 76° F (24.4° C), the ambient temperature inside the checkstand cannot be greater than 88.6° F (31.4° C). If the checkstand contains other heat producing equipment, you may need to use forced air to keep the temperature within the specified range. However, air coming into or leaving the checkstand MUST NOT enter or exit past the RealScan 7882 Scanner/Scale.

Electrical Wiring

Input

Voltage

Neutral and Ground Bus

L3

Main Service

Panel

 

Belt Control

Belt

N

Lighting

Motor

Misc. Equip.

G

 

Conduit

Circuit A: Checkstand

Checkstand

Frame

Note: The electrical wiring must meet all electrical codes, laws, and regulations.

Feeder wiring and insulated ground from main service panel to distribution panel to be run in metal conduit.

Isolated/Insulated

Circuit Breakers

 

Ground Bus

NCR circuits should be run in

 

separate metal Conduits.

 

Note: NCR circuits must be dedicated to

L1

NCR equipment or other logically

connected electronic equipment

 

 

(modems, DAA, bridges, etc.)

 

Circuit B: Terminal

L2

 

Neutral

Circuit C: Scanner

Receptacle should be easily

Bus

accessible and near the scanner

Distribution Panel

 

 

Isolated Ground Receptacles

Installation Type

Input Voltage

L1, L2

Circuit Breakers

 

 

 

 

U.S., Canada, &

100Vac to 120Vac

100Vac to 120Vac

Standard single-pole; value

Japan

 

 

determined by type of device

 

 

 

International

220Vac to 240Vac

220Vac to 240Vac

branch and by electrical code.

 

 

 

 

European

220Vac

220Vac

European double-pole.