NCR RealScan 7882 Installation and Owner Guide

Auxiliary RS-232 Port

The Auxiliary RS-232 Port provides a connection for an RS-232 device such as a RealScan 7837 Hand-Held Scanner. The following table gives wiring information about the connector.

Auxiliary RS-232 Port

Pin Number

Signal Name

1

+5 Vdc

2

NC

3

GND

4

TXD

5

RXD

6

+ 12 Vdc

7

CTS

8

RTS

9

Frame

10

Frame

NCR RealScan 7835/7836

1416-C313-0040 – Interface Cable

1416-C397-0010 – Extension Cable

NCR RealScan 7837

1416-C445-0025 – Interface Cable

1416-C397-0010 – Extension Cable

The NCR 7882 auxiliary RS-232 port hardware is limited to the following fixed parameters.

Baud Rate

4800 (9600 before SN 40-36009427)

Parity

Odd

Stop Bits

1

Number of Data Bits

7

Hardware Handshaking

None

Terminator Character

CRLF

UPC-A Prefix Character

d

UPC-E Prefix Character

d

EAN 8 Prefix Character

d

EAN 13 Prefix Character

d

Code 128 Prefix Character

f

Code 39 Prefix Character

a

Interleaved 2 of 5 Prefix Character

b

Note: ASCII data cannot be sent from the auxiliary RS-232 port when the RealScan 7882 is set for OCIA Short format. In this case, the RealScan 7882 generates an error beep.

When a 7836 is attached to a RealScan 7882, the 7836 requires the following programming.

Reset to serial (default values) – Label ZA

Enable code ID (default values) – Label FB

497-0419630 Release F

09/02

9 of 62

Page 9
Image 9
NCR 7882 manual Auxiliary RS-232 Port