NCR 7882 manual Programming Defaults, Communications Protocol, Good Read Tone, Timers, Bar Codes

Models: 7882

1 62
Download 62 pages 30.34 Kb
Page 14
Image 14
Programming Defaults

NCR RealScan 7882 Installation and Owner Guide

Programming Defaults

Scanning the Default programming tag sets most program parameters to factory defined values as shown in the following chart. However, some parameters do not have default values so they are not changed, they stay as they are programmed.

01 Communications Protocol

 

Protocol

No default value – remains as programmed

 

 

11 Good Read Tone

 

Tone On/Off

On

Tone Frequency

Choice 6 of 8 Levels

Tone Length

Choice 3 of 16 Levels

Tone Volume

Choice 4 of 8 Levels

Not-On-File Volume

Choice 2 of 8 Levels

 

 

12 Timers

 

Lockout Time

750 Milliseconds

Restart Lockout Timer

Off

Active Time

15 Minutes

 

 

13 Bar Codes – 1

 

UPC/EAN

Enable

Version D

Disable

Extend UPC-A To EAN-13

Disable

Extend UPC-E To UPC-A

Disable

Periodical Codes

Disable

Periodical Code Extension

2-Digit & 5-Digit

Send Data

Data As Decoded

 

 

14 Bar Codes – 2

 

Code 39

Disable

Minimum Characters Allowed

8

Full ASCII

Disable

Check Digit Present

Disable

Transmit Check Digit

Disable

Allow 1- or 2-Character Tags

Disable

 

 

15 Bar Codes – 3

 

Interleaved 2 of 5

Disable

Bar Code Length

Range Check

Value 1

08

Value 2

16

Check Digit Present

Disable

Transmit Check Digit

Disable

 

 

17 Bar Codes – 4

 

Code 128

Disable

Minimum Data Characters

3

UCC 128

Disable

 

 

14 of 62

09/02

497-0419630 Release F

Page 14
Image 14
NCR 7882 manual Programming Defaults, Communications Protocol, Good Read Tone, Timers, Bar Codes