Image 15
16 Label Identifiers

NCR RealScan 7882 Installation and Owner Guide

16 Label Identifiers

 

 

 

 

 

 

 

Identifier Type

 

 

Unique Prefix

 

 

 

Common Byte 1

 

 

5D

 

 

 

 

Common Byte 2

 

 

42

 

 

 

 

Bar Code Type

 

 

No Default value – remains as programmed

 

UPC-A UPC-E

EAN-8

EAN-13

Code 39

Code 128

I 2 of 5

Common Byte

0

0

0

0

2

2

2

Unique Identifier

41 Hex

45 Hex

46 Hex

46 Hex

31 Hex

33 Hex

32 Hex

 

 

 

 

 

 

 

 

20 RS-232 Parameters – 1

 

 

 

 

 

 

 

Baud Rate

 

 

9600

 

 

 

 

Parity

 

 

Odd

 

 

 

 

Stop Bits & Character Length

1 Stop Bit, 7-Bit Character

 

 

Handshake

 

 

RTS High Wait For CTS

 

 

 

 

 

 

 

 

 

 

21 RS-232 Parameters – 2

 

 

 

 

 

 

 

BCC Options

 

 

Disable

 

 

 

 

Interface Control

 

 

None

 

 

 

 

Check Digit

 

 

Enable UPC-A, Enable EAN-8,

 

 

 

 

Enable EAN-13, Disable UPC-E

 

 

 

 

 

 

 

 

 

22 RS-232 Prefix Byte

 

 

 

 

 

 

 

Prefix Byte

 

 

Disable

 

 

 

 

ASCII Code

 

 

02

 

 

 

 

 

 

 

 

 

 

 

 

23 RS-232 Terminator Byte

 

 

 

 

 

 

 

Terminator Byte

 

 

Enable

 

 

 

 

ASCII Code

 

 

03

 

 

 

 

 

 

 

 

 

 

 

24 RS-232 Communications Options

 

 

 

 

 

 

Message Delay

 

 

10 Milliseconds

 

 

 

Normal Or Eavesdrop Mode

 

Normal Mode

 

 

 

 

 

 

 

 

 

 

21 Miscellaneous Parameters

 

 

 

 

 

 

IBM Tone Control

 

 

Enable

 

 

 

 

IBM Rexmit Control

 

3 Times

 

 

 

 

IBM Tag Data Format

 

Hex

 

 

 

 

 

 

 

 

 

 

 

 

497-0419630 Release F

09/02

15 of 62

Page 15
Image 15