The contents of the Resident System Program (default

value) are given below in the following Table 310.1:

Table 310.1 Resident System Program Contents
FUNCTION DEFAULT VALUE
Recall

Button

Timing Time is 0.4 sec.
Pause Timing Time is 1.0 sec.
Paging Timeout Time is 60 sec.
Hold Recall Time is 60 sec.
System Refresh Basis Based on no change in status
Day Mode CO/PBX Ringing Assignment Stations 1 and 9 ring for all CO/PBX lines
Night Mode CO/PBX Ringing Assignment Stations 7 and 9 will ring
Door Phone Assignment Door Phone not assigned
Door Phone Chime Assignment Stations 1 and 9 chime
Off Hook Ringing Assignment Stations 1 and 9 ring
Internal Paging Zone Assignment No stations in any zone
Attendant Station Assignment 1 and 9 are attendant stations
Prime Line Pick-Up Assignment Not assigned
Prime Line Pick-Up for incoming Calls No prime line on incoming calls
Prime Line Assignment No private lines
CO/PBX Line Scan Assignment Scan goes from CO/PBX line 2 to 1
CO/PBX Line Assignment All lines are CO
PBX Access Code Assignment PBX access code “9” is assigned
CO/PBX Group Assignment All lines are group A
Station Class Assignment All stations are class 0 (non-restricted)
“1” + Dialing Assignment “1” + Dialing
Digit Rejection Assignment No digits rejected
Speed Dial Toll Override Assignment Toll restriction is overriden
Toll Restriction Override Table Assignment No 3-digit codes in table

/ . ...\

Page 300-2