Chapter 5 Normal Operation
III-64

(16) Display of detailed information about a specified controller in a specified disk array

If the -cn option is specified, the system displays detailed information about a specified controller in a specified
disk array.
Specify a disk array and controller as shown below.
-cn <Disk Array Name> <Abbreviated Name> <Resource Number>
(a) Basic Cabinet Junction Box (BC_JB)
# iSMview -cn Storage002 BC_JB 00h
--- BC Junction Box Information ---
Type : BC Junction Box
Abbreviated Name : BC_JB
Number(h) : 00
State : ready
Code(h) : 41-00
The display items are as follows:
(1) BC Junction Box Information
Displays the detailed information of the basic cabinet junction box.
Type: Resource type
(“BC Junction Box” is displayed.)
Abbreviated Name: Abbreviation of the resource (“BC_JB” is displayed.)
Number(h): Resource number
State: Resource state
ready: Normal state
fault: Abnormal state
Code(h): Code for identifying the resource type
(b) Cache Module (CHE)
# iSMview -cn Storage002 CHE 00h
--- Cache Module Information ---
Type : Cache Module
Abbreviated Name : CHE
Number(h) : 00
State : ready
Code(h) : a0-00
Capacity : 1.2GB
The display items are as follows:
(1) Cache Module Information
Displays the detailed information of the cache module.
Type: Resource type
(“Cache Module” is displayed.)
Abbreviated Name: Abbreviation of the resource (“CHE” is displayed.)