Chapter 5 Normal Operation
III-66
The display items are as follows:
(1) Battery Information
Displays the detailed information of the battery.
Type: Resource type
(“Battery” is displayed.)
Abbreviated Name: Abbreviation of the resource (“DAC_BBU” is displayed.)
Number(h): Resource number
State: Resource state
ready: Normal state
charge: Charging
fault: Abnormal state
Code(h): Code for identifying the resource type
(e) Fan (lower) (DAC_FANL)
# iSMview -cn Storage002 DAC_FANL 00h
--- FAN Information ---
Type : FAN
Abbreviated Name : DAC_FANL
Number(h) : 00
State : ready
Code(h) : 69-00
The display items are as follows:
(1) FAN Information
Displays the detailed information of the fan (lower).
Type: Resource type
(“FAN” is displayed.)
Abbreviated Name: Abbreviation of the resource (“DAC_FANL” is displayed.)
Number(h): Resource number
State: Resource state
ready: Normal state
fault: Abnormal state
Code(h): Code for identifying the resource type
(f) Fan (upper) (DAC_FANU)
# iSMview -cn Storage002 DAC_FANU 00h
--- FAN Information ---
Type : FAN
Abbreviated Name : DAC_FANU
Number(h) : 00
State : ready
Code(h) : 69-00