Chapter 5 Normal Operation
III-68
The display items are as follows:
(1) Temperature Information
Displays the detailed information of the temperature sensor.
Type: Resource type
(“Temperature” is displayed.)
Abbreviated Name: Abbreviation of the resource (“DAC_TEMP_ALM” is displayed.)
Number(h): Resource number
State: Resource state
ready: Normal state
fault: Abnormal state
Code(h): Code for identifying the resource type
(i) Disk Director (DD)
# iSMview -cn Storage002 DD 00h
--- Disk Director Information ---
Type : Disk Director
Abbreviated Name : DD
Number(h) : 00
State : ready
Code(h) : 90
Director Location : DA00
Port No.(h) : 00,01
The display items are as follows:
(1) Disk Director Information
Displays the detailed information of the disk director.
Type: Resource type
(“Disk Director” is displayed.)
Abbreviated Name: Abbreviation of the resource (“DD” is displayed.)
Number(h): Resource number
State: Resource state
ready: Normal state
fault: Abnormal state
offline: Not installed
Code(h): Code for identifying the resource type
Director Location: Location of the director.
Port No.(h): Director’s port numbers
* “---” is displayed for “Director Location” if a specified disk array is of the 100/1000/2000 series.