Troubleshooting
855-900547-200 4-1
CHAPTER 4 Troubleshooting
This chapter shows general actions to errors in the base module and peripheral units. If a
particular error persists to occur despite the actions you have taken, record the error state and
contact the maintenance personnel of NEC. See Figures 1-2 and 1-3 in Section 1.1 for the
locations of the main and expansion cabinets, respectively.

4.1. Troubleshooting

(1) AC power is not supplied when the AC power circuit breaker in PowerBay#0 and/or
PowerBay#1 at the lower part of the rear of the main cabinet.
Check that the distribution board is turned on.
Check that AC power is connected to the main cabinet.
Check that power cables are connected to POWER BAY#0 and POWER BAY#1.
Check that the DPSs are mounted on POWER BAY#0 and POWER BAY#1, and
operate normally.
(2) Nothing is displayed on the SP console.
Check that the SP console is turned on.
Check that the iSP-M card and the SP console in the main cabinet are connected
properly.
- Is the right cable used?
- Are the connectors firmly inserted?
- Is the IP address set correctly?
Check that the software does not disable screen display by moving the cursor and
pressing the SHIFT key on the screen.
Check that the console brightness is set to the proper level.
(3) Nothing is displayed on the VGA console (when the VGA is mounted).
Check that the VGA console is turned on.
Check that the VGA card on the I/O module and the VGA console are connected
properly.
- Is the right cable used?
- Are the connectors firmly inserted?
Check that the software does not disable screen display by moving the cursor and
pressing the SHIFT key on the screen.