Base Module
cmd | arg1 |
| arg2 |
| arg3 | arg4 | Description |
add | - | - |
| - |
| - | Use this command to manually inform the |
|
|
|
|
|
|
| iSP of an addition of components. iSP’s |
|
|
|
|
|
|
| management state will change from |
|
|
|
|
|
|
| “nonexist.” to |
|
|
|
|
|
|
| If no argument is specified or an argument |
|
|
|
|
|
|
| has an error, the add command help opens. |
|
|
|
|
|
|
| This command is always valid without regard |
|
|
|
|
|
|
| to the current system state (with the |
|
|
|
|
|
|
| exception of the PBAY, to which this |
|
|
|
|
|
|
| command is valid only if none of the |
|
|
|
|
|
|
| partitions is active). |
|
|
|
|
|
|
| This command is not valid to the CELL |
|
|
|
|
|
|
| Cards, XBX Cards, PCI Bay, or their |
|
|
|
|
|
|
| subcomponents if any of the partitions within |
|
|
|
|
|
|
| the system is booting up, shutting down, or |
|
|
|
|
|
|
| handling an error. |
| pbayx | - |
| - |
| - | Add Power Bays. |
|
|
|
|
|
|
| x is a Power Bay number. The allowable |
|
|
|
|
|
|
| value of x is as follows: |
|
|
|
|
|
|
| For 32Way: |
|
|
|
|
|
|
| 0, 1: Power Bay No. in the Main Cabinet |
|
|
|
|
|
|
| 2, 3: Power Bay No. in the Expansion |
|
|
|
|
|
|
| Cabinet |
|
|
|
|
|
|
| For 8Way: |
|
|
|
|
|
|
| 0: Power Bay No. inside the chassis |
|
|
|
|
|
|
| 1: Power Bay No. outside the chassis |
|
|
|
|
|
|
| For ISPF: |
|
|
|
|
|
|
| 0: Power Bay No. inside the chassis |
| dpsxy | - |
| - |
| - | Add DPS’s to Power Bays. |
|
|
|
|
|
|
| The meaning of x is identical to that for |
|
|
|
|
|
|
| argument pbay. |
|
|
|
|
|
|
| y is a DPS No. within a Power Bay |
| ispx | - |
| - |
| - | Add backup iSPs. |
|
|
|
|
|
|
| x is the physical number of an iSP (0 or 1). |
|
|
|
|
|
|
| Backup iSPs can only be added to the |
|
|
|
|
|
|
| 32Way model. |
| clkx | - |
| - |
| - | Add CLK Cards. |
|
|
|
|
|
|
| x is the physical number of the CLK Card (0 |
|
|
|
|
|
|
| or 1). |
|
|
|
|
|
|
| The CLK Card can only be added to the |
|
|
|
|
|
|
| 32Way model. |
| xbxcx | - |
| - |
| - | Add XBX Cards. |
|
|
|
|
|
|
| x is an XBX Card number |
|
|
|
|
|
|
| The SP will automatically recognize the |
|
|
|
|
|
|
| number of XBX LSI chips installed on the |
|
|
|
|
|
|
| XBX Card. |
| cellx | - |
| - |
| - | Add CELL Cards. |
|
|
|
|
|
|
| x is the physical number of the CELL Card |
|
|
|
|
|
|
| |
| procxy | - |
| - |
| - | Add processors. |
|
|
|
|
|
|
| x is the physical number of the CELL Card |
|
|
|
|
|
|
| |
|
|
|
|
|
|
| y is the location of the processor on the |
|
|
|
|
|
|
| CELL Card |