Lamp

Projector Options

Lamp Mode

This feature allows the lamp power supply to operate under three set- tings.

Maximum ..... This setting consumes maximum current from the AC input

and results in the most light output.

NOTE: The Maximum mode shortens the lamp life. Be sure to use this mode at temperature of 95˚ F (35˚C) or less.

Medium ....... This setting allows the lamp power supply to draw a medium

amount of current from the AC input source and allows for medium power consumption.

Minimum ..... This setting consumes minimum current from the AC input

and results in the least light output.

Reference White Balance

This feature adjusts the white balance that is used as a reference. This adjustment affects all sources. The Ref.White Bal. is available for test pattern only.

Factory Default

Returns all adjustments and settings to the factory preset level.

All Data .......................

Reset all the settings for all the signals to the factory

 

preset.

NOTE: The items that can be reset are all the settings and adjusts except for Language, Projector ID, Lamp Hour Meter, Projector Usage and Communication Speed.

 

Including Entry List

 

Also deletes all the signals in the Entry List and re-

 

turns to the factory preset.

Current Signal .............

Resets the adjustments for the current signal to the

 

factory preset levels.

NOTE: All the items in "Adjust (Source)" can be reset.

Enables you to set preferences and other operating options.

Timer

Enables you to turn on or off your projector automatically at a specified time. Two timer functions are available: On/Off Timer and Sleep Timer.

On/Off Timer

Up to eight settings can be programmed.

Before setting On/Off Timer, make sure that Date, Time Preset feature is set.

Even after setting On/Off Timer, turning the projector on or off with the remote control is possible.

There are two time display formats: 24-hour or AM/PM format.

1.Open the On/Off Timer window.

2.Select EDIT and press ENTER on the remote control to open the EDIT window.

3.Set the Week, Day, On-Time and Off-Time using the Select buttons and Source buttons (1 thru 10). To cancel the on-time or off time, use Delete.

4.Select Set and press the ENTER button on the remote control to complete the setting. To close, select Close.

E – 36