4.2.4SET

MULTI CONTROL

In edit mode it increases to the next digit.

4.2.4SET

A press on SET unlocks a digit to access edit mode.

When unlocked, the digits are ”active” (flashes) and can be edited by pressing MINUS, PLUS and PAGE as required.

When finished editing, lock the digit by another press on SET.

4.2.5Clear / cancel / reset

A press on CLEAR, clear digits, cancel alarms or resets the counters.

4.2.6

Calibration

 

To access calibration mode, press and hold SET more than 2

2 sec

seconds.

 

 

To return to main-function mode, press SET when the text return

 

(RET) is shown.

 

4.2.7

Lighting

 

The instrument uses red back lighting for the display and the 4 push-buttons. The lighting can be set at 4 different levels.

2 sec

To quick access the light control, press and hold PAGE for more than 2 seconds. The flashing text (Lit OFF) will be displayed and the display will be lit momentarily.

To select between the 4 light levels, Press PLUS: LOW, MED,

MAX and OFF. To lock the selected level press SET.

The selected light level will be copied to all NX2 instruments connected to the system. When the lighting is on, it is not possible to reduce or turn off the lighting on an individual instrument.