12.5.10 C67 WIND SPEED ALARM (WSA)

MULTI CONTROL

12.5.10 C67 WIND SPEED ALARM (WSA)

To set a wind speed alarm level. The buzzer will sound when the true wind speed is higher than the set level. To switch of the alarm, set C67 to 00. To silence an alarm, press any key.

The alarm level is set from 1 to 50 m/s.

To set the alarm level, press SET. To select level, press PAGE, PLUS or MINUS as required. To store the selected value, press SET.

Note! The Alarm level is always set in m/s regardless of unit used for displaying!

If the set alarm level is reached and the alarm Is silenced, the wind speed must drop below 50% of the set alarm level to be activated again.

12.6 C70, calibration of Network and NMEA

When calibration code C70 is selected, the LCD arrows for all functions will be displayed

12.6.1C70 (RET)

To return to the normal mode, press SET.

12.6.2C71 (OFF KEY)

(On) = Sound when push buttons are pressed. (OFF) = no sound.

12.6.3C72 (d0 SEA)

Damping of speed and course over ground (SOG/COG), affecting the complete Nexus Network and NMEA output.

d0 = no damping. d1 = 2 sec, d2 = 5 sec, d3 = 10 sec, d4 = 20 sec, d5 = 40 sec, d6 = 1.20 min, d7 = 2.40 min, d8 = 5 min and d9 = 10 min.

12.6.4C73 (OFF BSP)

(OFF) = NX2 log transducer. (On) = NMEA log transducer.

If you want to use a NMEA transducer (connected to the NMEA input, you have to set C73 to On. The Server will then transmit this information on the Nexus Network to all connected instruments.

After you have changed this setting, you have to restart the system

12.6.5C74 (OFF DEP)

(OFF) = NX2 depth transducer. (On) = NMEA depth transducer.

If you want to use a NMEA transducer (connected to the NMEA input, you have to set C74 to On. The Server will then transmit this information on the Nexus Network to all connected instruments.

After you have changed this setting, you have to restart the system