Nexus 21 Multi Control 7.5Set and turn on anchor alarm ANC, 7.6Clear an alarm value

Models: Multi Control

1 68
Download 68 pages 17.95 Kb
Page 26
Image 26
7.5Set and turn on anchor alarm (ANC)

MULTI CONTROL

7.4Set and turn on shallow (SHA) and depth alarm (DEA)

Select shallow (SHA) or depth (DEA) alarm, press SET. The first digit in the previous value flashes.

If you want to reset the previous value to zero (0), Press CLEAR. To select desired depth press MINUS, PLUS and PAGE as required.

Press SET to lock the selected value.

By this last press on SET, you have turned on the selected alarm function, which is indicated by the minute sign ( ´ ) above the last depth digit in the sub-function.

7.5Set and turn on anchor alarm (ANC)

Select anchor alarm (ANC), press SET. The first digit flashes.

The instrument will suggest a value for the shallow (SHA) alarm (actual depth minus 1,5 m / 5 FT).

To store the value press SET, or select your own depth as in 7.3. The minute sign ( ´ ) is shown above the last depth digit in the sub-function.

The instrument will suggest a value for the depth (DEA) alarm (actual depth plus 1,5 m / 5 FT).

To store the value press SET, or select your own depth as in 7.3. The minute sign ( ´ ) is shown above the last depth digit in the sub-function.

7.6Clear an alarm value

Select the alarm function to be cleared, press SET. The first digit flashes.

To clear the alarm, press CLEAR. All digits are set to zero (0). Press SET to lock the function.

7.7Silencing an alarm

To silence a triggered alarm that sounds and flashes, press ANY button.

The sound is silenced and the flashing stops.

The alarm is only triggered again if the selected depth value is exceeded (shallower or deeper) by 2 m (6 feet).

7.8Turning off / on an alarm

Select the alarm function to be turned off / on.

To turn the alarm off / on, press CLEAR.

The minute sign ( ´ ) disappears / appears.

25

Page 26
Image 26
Nexus 21 Multi Control operation manual 7.5Set and turn on anchor alarm ANC, 7.6Clear an alarm value, 7.7Silencing an alarm