Nikon CM200 service manual Radio Tuning Setup, Initial Test Equipment Control Settings

Models: CM200

1 70
Download 70 pages 31.35 Kb
Page 46
Image 46

4-4

RADIO TUNING AND PROGRAMMING

 

 

7.0Radio Tuning Setup

A personal computer (PC), Windows 95/98/NT and a tuner program are required to tune the radio. To perform the tuning procedures, the radio must be connected to the PC, radio interface box (RIB), and test equipment setup as shown in Figure 4-6.

ELM Adapter cable FKN8113

 

 

Radio

ACC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DC

 

 

 

 

 

 

 

 

 

 

 

 

 

RF

 

 

 

 

 

 

 

 

 

 

 

 

 

Audio In

Tx

Audio Generator

Test Box

 

 

RLN4460

Rx

Sinad Meter

Program/Test Cable

 

 

 

 

 

 

RKN4083

 

 

AC Voltmeter

 

 

 

 

DB15

 

 

RIB

 

Tx Data

 

RLN-4008

 

Rx Data

 

 

 

Gnd

 

Power

Cable 3080369B72 (9 PIN)

 

Supply

Cable 3080369B71 (25 PIN)

 

30 dB Pad

 

 

Service Monitor

 

 

 

 

Transmit

 

or Counter

 

 

 

 

 

 

Wattmeter

 

Receive

RF Generator

 

 

Figure 4-6Radio Tuning Test Equipment Setup with External RIB

7.1Initial Test Equipment Control Settings

The initial test equipment control settings are listed in Table 4-2.

Table 4-2Initial Equipment Control Settings

Service Monitor

Test Set

Power Supply

 

 

 

Monitor Mode: Power Monitor

Speaker set: A

Voltage: 13.8 Vdc (low

 

 

power models)

 

 

13.6 Vdc (high power

 

 

models)

 

 

 

RF Attenuation: -70

Speaker/load:

DC on/standby:

 

Speaker

Standby

 

 

 

AM, CW, FM: FM

PTT: OFF

Volt Range: 20 V

 

 

 

Oscilloscope Source: Mod

 

Current: 20A

Oscilloscope Horizontal: 10mSec/Div

 

 

Oscilloscope Vertical: 2.5 kHz/Div

 

 

Oscilloscope Trigger: Auto

 

 

Monitor Image: Hi

 

 

Monitor BW: Nar

 

 

Monitor Squelch: mid CW

 

 

Monitor Volume: 1/4 CW

 

 

 

 

 

NOTE Refer to Tuner on-line help files for tuning procedures.

Page 46
Image 46
Nikon CM200 Radio Tuning Setup, Initial Test Equipment Control Settings, Service Monitor Test Set Power Supply