2-8

MAINTENANCE

 

 

Figure 2-8PA Shield and DC Cable Removal (for High Power Models)

6.5PA Clip and Main PCB Removal (for Low Power Models)

1.Remove the screw that attaches the PA clip to the chassis. See Figure 2-9.

2.Remove the PA clip.

3.Remove all the screws that fix the PCB to the chassis.

4.Loosen the M2 screw (about 3 to 4 turns) on the RF connector using hex tool (Part number: 6680334F39).

5.Loosening this screw, enables you to unscrew the RF connector from outside.

6.Carefully remove the main PCB in a diagonal manner.

NOTE It is recommended to grip the volume potentiometer and remove the PCB board

Main PCB

PA Clip

M2 Screw

 

 

 

Figure 2-9PA Clip and Main PCB Removal (for Low Power Models)