MAINTENANCE | |
|
|
10.0Test Equipment
Table
.
Table
Motorola Part No. | Description | Characteristics | Application |
|
|
|
|
R2000, R2600 | Service Monitor | This monitor will | Frequency/deviation meter and sig- |
R2400, or R2001 |
| substitute for items | nal generator for |
| listed below with an | shooting and alignment | |
with trunking |
| ||
| asterisk * |
| |
option for Pri- |
|
| |
|
|
| |
vacy Plus™ and |
|
|
|
Smartnet Sys- |
|
|
|
tems™ † |
|
|
|
*R1049 | Digital Multimeter |
| Two meters recommended for AC/ |
|
|
| DC voltage and current measure- |
|
|
| ments |
|
|
|
|
*S1100 | Audio Oscillator | 67 to 200Hz tones | Used with service monitor for injec- |
|
|
| tion of PL tones |
|
|
|
|
*S1053, | AC Voltmeter, | • 1 mV to 300 V | Audio voltage measurements |
*SKN6009, | Power Cable | • 10 MΩ input imped- |
|
*SKN6001 | for meter, | ance |
|
| Test leads for meter |
|
|
|
|
|
|
R1053 | 20 MHz bandwidth, | Waveform measurements | |
| scope | 5 mV/cm - 20 V/cm |
|
|
|
|
|
R1443A | Broadband Watt- |
| Transmitter power output measure- |
| meter |
| ments |
|
|
|
|
S1339 | RF Millivolt Meter | 100 ∝V to 3 VRF, 10 | RF level measurements |
|
| kHz to 1.2 GHz |
|
|
|
|
|
*R1013 | SINAD Meter |
| Receiver sensitivity measurements |
|
|
|
|
S1348 (prog) | DC Power Supply | Bench supply for 13.8Vdc | |
|
|
|
|