Nikon CM200 service manual Test Equipment

Models: CM200

1 70
Download 70 pages 31.35 Kb
Page 34
Image 34

2-20

MAINTENANCE

 

 

10.0Test Equipment

Table 2-6 lists test equipment required to service the radio and other two-way radios

.

Table 2-6Recommended Test Equipment

Motorola Part No.

Description

Characteristics

Application

 

 

 

 

R2000, R2600

Service Monitor

This monitor will

Frequency/deviation meter and sig-

R2400, or R2001

 

substitute for items

nal generator for wide-range trouble-

 

listed below with an

shooting and alignment

with trunking

 

 

asterisk *

 

option for Pri-

 

 

 

 

 

vacy Plus™ and

 

 

 

Smartnet Sys-

 

 

 

tems™

 

 

 

*R1049

Digital Multimeter

 

Two meters recommended for AC/

 

 

 

DC voltage and current measure-

 

 

 

ments

 

 

 

 

*S1100

Audio Oscillator

67 to 200Hz tones

Used with service monitor for injec-

 

 

 

tion of PL tones

 

 

 

 

*S1053,

AC Voltmeter,

• 1 mV to 300 V

Audio voltage measurements

*SKN6009,

Power Cable

• 10 Minput imped-

 

*SKN6001

for meter,

ance

 

 

Test leads for meter

 

 

 

 

 

 

R1053

Dual-trace Oscillo-

20 MHz bandwidth,

Waveform measurements

 

scope

5 mV/cm - 20 V/cm

 

 

 

 

 

R1443A

Broadband Watt-

 

Transmitter power output measure-

 

meter

 

ments

 

 

 

 

S1339

RF Millivolt Meter

100 V to 3 VRF, 10

RF level measurements

 

 

kHz to 1.2 GHz

 

 

 

 

 

*R1013

SINAD Meter

 

Receiver sensitivity measurements

 

 

 

 

S1348 (prog)

DC Power Supply

0-20 Vdc, 0-20 Amps

Bench supply for 13.8Vdc

 

 

 

 

Page 34