Nilfisk-ALTO SR1800C B-D Motor overheating SR 1800C B, User Manual, 3301481722006-06A

Models: SR1800C B-D

1 110
Download 110 pages 56.69 Kb
Page 64
Image 64
Motor overheating (SR 1800C B)

Manual background USER MANUAL

Motor overheating (SR 1800C B)

PROBLEM

CAUSE

REMEDY

Overload

Current to the motor

Subject the motor to less strain

Insufficient air flow

Check suction/delivery openings

Clean or change shields or caps

 

Fan rotation

Replace fan

Wrong voltage

Low battery voltage

Recharge batteries

 

Low voltage to motor terminals

Check connections for proper tightening

Bearings

Faulty or badly installed bearing

Change bearings or change at every repair

 

 

operation

 

Radial overload

Check stress and strain

 

Dirt infiltration

Clean the motor inside

Winding heating

Armature with shorted blackened winding

Replace. Use only original spares. Do not

 

 

rewind.

 

High humidity

Clean and dry at 110°C

 

Shorted coil or winding, blackened insulating

Replace. Use only original spares.

 

material

 

 

Loose inner connection

Check and tighten correctly

Commutator heating

Short-circuit between segments

Clean commutator and contact the

 

 

manufacturer

 

Poor contact or worn carbon brushes

Check or replace

 

Improper carbon brush quality

Only original carbon brush and for 48 V

 

 

voltages

 

Excessive spring pressure

Recalibrate or change

 

Dirty or damaged surface

Clean or rectify the commutator