CC100Master Bridge User’s Guide

We bind MAC address 00-60-64-12-34-56 to port LAN1 and MAC address 00-60-64-78-90-00 to port LAN2,

Reboot System

Reboot Master CC100 only and leave the EP untainted.

Default Setting

Restore all settings of the CC100 to factory default, including username/password, IP address, privacy mode/key, etc. Press the ‘Reset’ button locally for about 5 seconds and the CC100 will reboot.

Upload Firmware

Upload ‘Bootcode’ / ‘System firmware’ / ‘Master driver (3110)’ / ‘EP driver (3010 or 3110)’ / ‘Diagnosis utility’ onto the CC100 ‘Upload Area’. Not functional yet, wait to ‘Activate Firmware’ or to ‘Upgrade’ driver. Refer to the following “Example to Upload then Activate System Firmware and HCNA Driver” for more details.

Activate Firmware

To do the real upgrade for ‘Bootcode’ or ‘System Firmware’, make the previous uploaded image functional. Refer the following “Example to Upload then Activate System Firmware and HCNA Driver” for more details.

Backup/Restore Configuration

Use to backup current configuration into a file with filename extension ‘.shc’. Or to restore the CC100 configuration form the previous saved file.

Example to Upload then Activate System Firmware and HCNA Driver

It is a 2-stage file upgrade procedure, first to upload the selected file onto the CC100 flash ROM ‘Upload Area’, then to ‘Activate’ it. A coax network system with one CC100 and two connected Smart EPs.

Current System Firmware and HCNA Driver Version

The system firmware version is ’3.34’ before upgrade, check the ‘Information’ window,

26

Page 29
Image 29
Nokia CC100 manual Reboot System, Default Setting, Upload Firmware, Activate Firmware, Backup/Restore Configuration