Image 7

CC100Master Bridge User’s Guide

You can also use other Combiner’s or Mixer-Splitter’s with the CC100 to build the same system. See the following Figure 3 for different cabling.

Figure 3: Different Cabling of CC100

NOTE: After powering up the CC100, the LED ‘SynMode’ will always be glowing and LED ‘Link/Act’ will light up if at least one EP is detected on the HCNA network. A dimmed LED ‘Link/Act’ shows if no EP is attached to the HCNA network.

NOTE: The minimum attenuation between Master and EP is 12dB. The EP is usually connected to the coaxial cable via a Tap device that provides enough attenuation (contributes more than 20dB). If you intend to connect the Master and EP directly for test purposes, please add the attenuator that exceeds 12dB to the coaxial cable.

Verification

After you have finished the installation, you should be able to access the CC100 through Ethernet link.

4