For G6RC, G6RD and G6RL Residential Furnaces

BLUE

BLUE

 

BLUE

 

BLOWER

SUPPLY AIR

FLAME ROLL-OUT

 

DECK SWITCH

LIMIT SWITCH

SWITCH

 

 

(SELECT MODELS

(ALL MODELS)

(ALL MODELS)

 

ONLY)

 

 

 

 

 

 

 

BLUE BLUE

ORANGE ORANGE

 

WHITE (NEUTRAL)

 

 

 

 

BLACK 120V

 

 

 

 

GROUND

 

 

 

 

ROOM THERMOSTAT

 

 

 

 

R

 

 

 

 

Y

 

 

 

 

G

 

 

 

 

W

 

 

 

 

AIR CONDITIONER

 

 

 

 

CONDENSING UNIT

 

 

 

 

C

 

 

 

 

Y

 

 

 

FLAME SENSOR

 

 

 

 

RED

 

 

 

 

YELLOW

 

 

 

BROWN

 

 

 

GAS

 

 

 

 

VALVE

 

 

 

 

 

IGNITOR

 

 

Legend

 

 

BLACK

 

 

BLACK

Field Wiring

 

R

C

BLACK

 

 

 

 

Factory Wiring:

INDUCER

 

Low Voltage

 

BLACK

 

 

 

High Voltage

 

 

 

 

 

 

 

STATUS

FAULT CONDITION

 

RED

 

LIGHT

 

 

 

Power On

 

 

 

ON

Limit Circuit Open

 

1 FLASH

Pressure Switch Stuck Open

 

2 FLASHES

Pressure Switch Stuck Closed

 

3 FLASHES

Ignition Failure (Check Ground)

 

4 FLASHES

115 VAC & Neutral Reversed or no Ground 5 FLASHES

False Flame or Gas Valve Relay Shorted

Continuous

Power Off

 

 

 

OFF

 

 

 

FLAME

FAULT CONDITION

 

YELLOW

 

LIGHT

Low Flame Sensor Signal

 

Continuous

 

 

 

Flash

Flame Present

 

 

 

ON

VENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PRESSURE

VENT

SAFETY

SWITCH

PRESSURE SWITCH

SWITCH

 

 

 

 

(93+ MODELS ONLY)

(ALL MODELS)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WHITEBLACK

BLOWER DOOR

SWITCH

GREEN

TRANSFORMER

 

WHITE W/ BLK STRIPES

WHITE

24 V

120 V

BLK W/ WHITE STRIPES

BLACK

180 120 90 60

BLACK

 

 

3 OR 4 SPEED MOTOR

 

 

 

C

 

 

 

 

 

 

 

H

 

 

 

 

 

MH

 

 

 

L

ML

 

 

 

 

 

 

 

 

WHITE

RED

ORANGE

BLUE

BLACK

RED

1

 

 

 

 

 

 

 

 

 

ORANGE

2

 

 

 

 

 

 

 

 

 

BLUE

3

 

 

 

 

 

 

 

 

 

BLACK

4

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

WHITE

6

 

 

 

 

 

 

 

 

 

 

MOTOR

 

 

 

 

 

PLUG

 

 

 

 

THESE WIRES ARE

NOT PRESENT

ON 3 SPEED

MODELS

If any of the original wire as supplied with the furnace must be replaced, it must be replaced with wiring material having a temperature rating of at least 105 C.

Figure 26. G6RC, G6RD and G6RL Integrated Control Board System Diagram

30

Page 30
Image 30
Nordyne G6RL 90+ For G6RC, G6RD and G6RL Residential Furnaces, G6RC, G6RD and G6RL Integrated Control Board System Diagram