INSTALLATION REQUIREMENTS Requirements and Codes
This furnace must be installed in accordance with these instructions, all applicable local build- ing codes, and the current revision of the Na- tional Fuel Gas Code
American National Standards Institute, Inc. 1430 Broadway
New York, New York 10018
Canada installations shall comply with CAN/
•
•
These publications are available from: National Fire Protection Association, Inc. Batterymarch Park
Quincy, Massachusetts 02269
!WARNING:
This furnace is not approved for in- stallation in mobile homes. Installa- tion in a mobile home could cause fire, property damage, and/or personal injury.
Model | Furnace |
| Dimensions (inches) |
| Shipping | ||
Number | Btuh |
|
|
|
| Weight | |
A | B | C | D | ||||
(lbs) | |||||||
|
| ||||||
|
|
|
|
|
| ||
G6R(C,D)040C | 40,000 | 14 1/4 | 12 3/4 | 5 1/8 | 11 3/4 | 133 | |
G6R(C,D)060C | 60,000 | 14 1/4 | 12 3/4 | 5 1/8 | 11 3/4 | 140 | |
G6R(C,D)080C | 80,000 | 19 3/4 | 18 1/4 | 7 7/8 | 17 1/4 | 172 | |
G6R(C,D)100C | 100,000 | 19 3/4 | 18 1/4 | 7 7/8 | 17 1/4 | 180 | |
G6R(C,D)120C | 120,000 | 22 1/2 | 21 | 9 1/4 | 20 | 204 | |
G6RL040C | 40,000 | 14 1/4 | 12 3/4 | 4 5/8 | 12 3/4 | 135 | |
G6RL060C | 60,000 | 14 1/4 | 12 3/4 | 4 5/8 | 12 3/4 | 135 | |
G6RL080C | 80,000 | 19 3/4 | 18 1/4 | 10 | 18 1/4 | 174 | |
G6RL100C | 100,000 | 19 3/4 | 18 1/4 | 10 | 18 1/4 | 185 |
Table 3. Furnace Dimensions and Shipping Weights
CLEARANCES TO COMBUSTIBLE MATERIALS
This furnace is Designed Certified by AGA/CGA Laboratories for the minimum clearances to combustible material listed in Table 4. See the furnace name plate, located inside the furnace cabinet, for specific model number and clearance information.
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIAL
| Furnace | Cabinet |
| Minimum Clearances (Inches) |
| ||
| Input | Width |
|
|
|
|
|
| (Btuh) | (Inches) | Side | Vent | Back | Top | Front |
40,000 | 14 1/4 | 0 | 0 | 0 | 1 | 1* | |
60,000 | 14 1/4 | 0 | 0 | 0 | 1 | 1* | |
80,000 | 14 1/4 | 0 | 0 | 0 | 1 | 1* | |
100,000 | 19 3/4 | 0 | 0 | 0 | 1 | 1* | |
120,000 | 22 1/2 | 0 | 0 | 0 | 1 | 1* |
* 24 inches is the minimum clearance for servicing.
36 inches is the recommended clearance for service.
Table 4. Minimum Clearances to Combustible Materials