Nortec NHPC, NHTC manual 10-10, Load Calculation Summary Sheet, Page 14, Outdoor relative humidity

Models: NHPC NHTC

1 125
Download 125 pages 49.33 Kb
Page 22
Image 22
Outdoor relative humidity

Table 1. Outdoor/Indoor Relative Humidity Conversion Chart

Outdoor relative humidity

100%

95%

90%

85%

80%

75%

70%

65%

60%

55%

50%

45%

40%

35%

30%

25%

20%

15%

10%

5%

0%

2

4

5

6

7

9

12

17

19

23

29

36

43

52

2

3

4

6

7

9

12

16

17

22

28

34

41

50

2

3

4

5

6

8

11

15

16

21

26

31

39

48

2

3

4

5

6

8

11

14

15

20

24

29

37

45

2

3

4

5

6

7

10

13

15

19

23

27

35

42

2

3

4

4

5

7

10

12

14

18

22

26

33

39

1

2

3

4

5

6

9

11

13

17

20

24

31

36

1

2

3

4

4

5

8

10

12

15

19

23

29

34

1

2

3

3

4

5

7

9

11

14

17

21

26

31

1

1

3

3

4

4

7

8

10

13

16

19

24

29

1

1

2

3

3

4

6

8

9

12

14

18

22

26

1

1

2

3

3

4

6

7

8

11

13

16

20

24

1

1

2

2

3

4

5

7

7

10

12

14

18

21

1

1

2

2

2

4

5

6

6

9

10

12

15

18

0

1

2

2

2

3

4

5

6

7

9

11

13

15

0

1

1

1

2

3

3

4

5

5

7

9

11

13

0

1

1

1

2

2

3

3

4

5

5

7

9

10

0

0

1

1

1

1

2

3

3

4

4

5

6

8

0

0

0

1

1

1

2

2

2

3

3

3

4

6

0

0

0

0

0

0

1

1

1

2

2

2

3

3

0

0

0

0

0

0

0

0

0

0

0

0

0

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

-20°

-10°

-5°

+5°

+10°

+15°

+20°

+25°

+30°

+35°

+40°

+45°

+50°

Outdoor temperature

Chart shows what the residual indoor RH would be at 70°F under varying outdoor conditions if a proper humidification system were not installed in the building. Studies indicate that the recommended RH should be between 40% and 60% for optimum benefits to the occupants.

Table 2. Load Calculation Summary Sheet

Determine the moisture required in the space (Table 3)

 

 

 

Grains from Table 3 at space temp. ______ x Indoor RH

= A ______ gr/ft3

 

Determine the moisture level of incoming air (Table 4)

 

 

 

Grains from Table 4 at space temp. ______ x Outdoor RH

= B ______ gr/ft3

 

Therefore: moisture to be added: (moisture) M - A - B ______ gr/ft3

 

M ______ gr/ft3

Determine the volume of air to be humidified. Choose the largest

 

 

value.

 

 

1.

Natural ventilation: Volume x number of air changes.

______ ft3/hr

 

2.

Exhaust air: CFM x 60 min/hr

______ ft3/hr

 

3.

Make-up air: CFM x 60 min/hr

______ ft3/hr

C ______ ft3/hr

Therefore: Gross humidification load = L (load) = MxC = ______ lbs/hr

L ______ lbs/hr

 

 

7,000

 

 

 

NOTES: 1. 7,000 grains = 1 pound

2. If HVAC system uses economizer cycle, check load using formula 6.

10-10

Page 14 2008-10-01

Page 22
Image 22
Nortec NHPC, NHTC manual 10-10, Load Calculation Summary Sheet, Page 14, Outdoor relative humidity, Outdoor temperature