Important Safety Instructions

Important Regulatory Information

Important Safety Instructions

1.Read and follow all warning notices and instructions marked on the product or included in the manual.

2.The AC product version is intended to be used with a 3-wire grounding type plug ± a plug which has a grounding pin. This is a safety feature. Equipment grounding is vital to ensure safe operation. Do not defeat the purpose of the grounding type plug by modifying the plug or using an adapter.

Prior to installation, use an outlet tester or a voltmeter to check the ac receptacle for the presence of earth ground. If the receptacle is not properly grounded, the installation must not continue until a qualified electrician has corrected the problem.

If a 3-wire grounding type power source is not available, consult a qualified electrician to determine another method of grounding the equipment.

3.Slots and openings in the cabinet are provided for ventilation. To ensure reliable operation of the product and to protect it from overheating, these slots and openings must not be blocked or covered.

4.Do not allow anything to rest on the power cord and do not locate the product where persons will walk on the power cord.

5.Do not attempt to service this product yourself, as opening or removing covers may expose you to dangerous high voltage points or other risks. Refer all servicing to qualified service personnel.

6.General purpose cables are provided with this product. Special cables, which may be required by the regulatory inspection authority for the installation site, are the responsibility of the customer.

7.When installed in the final configuration, the product must comply with the applicable Safety Standards and regulatory requirements of the country in which it is installed. If necessary, consult with the appropriate regulatory agencies and inspection authorities to ensure compliance.

8.A rare phenomenon can create a voltage potential between the earth grounds of two or more buildings. If products installed in separate buildings are interconnected, the voltage potential may cause a hazardous condition. Consult a qualified electrical consultant to determine whether or not this phenomenon exists and, if necessary, implement corrective action prior to interconnecting the products.

9.Input power to the DC voltage configurations of this product must be provided by one of the following: (1) a National Electrical Code (NEC)/Canadian Electrical Code (CEC) Class 2 circuit for use in North America, or (2) a certified Safety Extra Low Voltage (SELV) /Limited Power Source (LPS) input for use in the country of installation.

10.In addition, if the equipment is to be used with telecommunications circuits, take the following precautions:

ÐNever install telephone wiring during a lightning storm.

ÐNever install telephone jacks in wet locations unless the jack is specifically designed for wet locations.

ÐNever touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the network interface.

ÐUse caution when installing or modifying telephone lines.

ÐAvoid using a telephone (other than a cordless type) during an electrical storm. There may be a remote risk of electric shock from lightning.

ÐDo not use the telephone to report a gas leak in the vicinity of the leak.