Profile

30 AT commands

Profile

A proÞle deÞnes a CTA 500dm set-up. Each proÞle deÞnes the rate adaptation protocol and the options used with that protocol, the bearer capability and data rate of the next call dialed, the bearer capabilities and acceptable data rates for inbound calls, and the detailed operation of the serial interface port.

The proÞle does not include stored dial strings.

Three types of proÞles are available:

¥The factory default which is Þxed.

¥The user proÞle which is programmable by the user and is stored in non-volatile memory.

¥The active proÞle which is dynamic while the CTA 500dm is in operation. It records changes made using AT commands. When the CTA 500dm is powered down, the active proÞle is lost, unless it is saved as the user proÞle. On power-up, the active proÞle is loaded from one of the saved proÞles.

The factory proÞle is proÞle 0 and the user proÞle is proÞle 1.

Profile commands summary

Command

Description

 

Value

 

 

 

 

 

&Fn

load active profile

 

0

factory profile (default)

 

from factory profile

 

1

user profile

 

 

 

 

 

 

 

 

Zn

load active profile

 

0

factory profile

 

from stored profile

 

1

user profile (default)

 

 

 

 

 

 

 

 

&Yn

select profile to load

 

0

factory profile (default)

 

into active profile on

power-up

1

user profile

 

 

 

 

 

 

 

&W

save active profile to memory

 

 

 

 

 

 

 

CTA 500dm On Line Guide

P0873832 Issue 05