AT commands 53
MP
The following command is available for CTA 500dm versions that support MP.
MP command summary
Command | Description | Value | |
|
|
|
|
@B0=n | set number of links | 1 | single channel used |
| in MP bundle | 2 | both channels used (default) |
|
| ||
|
|
|
|
Rate Multiplier
The Rate Multiplier Command
@B0=value
controls the number of links used when the CTA 500dm is operating in the MP mode.
A value of 1 indicates that a single link may be used. A value of 2 indicates that two links may be used. The default value is 2.
Result Codes
OK Appears when the value is supported.
ERROR Appears when the selected value is not recognized or is not supported.
CTI MUX Mode
The CTI MUX mode command
ATCTI
activates the ACCESS multiplexer functionality on the CTA 500dm. Automatically issued when ACCESS/TAPI is being installed on the PC using the CTA 500dm.
P0873832 Issue 05 | CTA 500dm On Line Guide |