74 Troubleshooting
properties. Ensure ÒUse country and area codeÓ is deselected if using MP with two dial out numbers.
The PC receives bad data after a data call connection.
¥Make sure that the CTA 500dm and the remote device are set to the same rate adaptation protocol. See ÒRate adaptation protocol speciÞcationsÓ on page 80 for more information.
¥The remote device may be conÞgured for synchronous transmission. The CTA 500dm does not support synchronous operation.
The CTA 500dm loses data after a data call connection.
¥Make sure that the CTA 500dm and PC ßow control methods match. SeeÒFlow ControlÓ on page 57 for more information.
The CTA 500dm hangs up during a data call.
¥Check the setting of the DTR pin. See ÒDTR OperationÓ on page 59 for more information.
Data calls are established but Internal applications time out.
¥Check that the settings under TCP/IP properties match those of your ISP.
Data calls are made using MP and the connected
¥Only one channel may be available at the destination (for instance if the ISP is busy).
¥Check that you are subscribing to an MP capable service.
¥Only one channel is available in the outgoing line pool.
¥You are active on a voice call. If the voice call ends, a 128 kbit/s session will be established.
CTA 500dm On Line Guide | P0873832 Issue 05 |