Appendix 83
Numeric CTA 500dm responses
Numeric response | Indication |
|
|
0 | OK |
|
|
1 | RING |
|
|
2:number | RING:number |
|
|
3 | NO CARRIER |
|
|
4 | ERROR |
|
|
6 | NO DIALTONE (not used) |
|
|
7 | BUSY |
|
|
56 | CONNECT 56000 |
|
|
64 | CONNECT 64000 |
|
|
112 | CONNECT 112000 |
|
|
120 | CONNECT 120000 (if supported) |
|
|
128 | CONNECT 128000 |
|
|
1000 | SEND PROGRAM FILE USING |
|
|
Initialization strings
The following table shows some suggested initialization strings. In all examples, Flow Control is set to hardware (\q3) and DTR Operation is set to hang up (&d2).
Protocol | Bearer service | Rate (kbit/s) | Initialization string |
|
|
|
|
PPP | data | 64 | \q3 &d2 %a2=95 %a98=0 %a4=0 |
|
|
|
|
PPP | data | 56 | \q3 &d2 %a2=95 %a98=0 %a4=1 |
|
|
|
|
PPP | audio | 56 | \q3 &d2 %a2=95 %a98=1 %a4=1 |
|
|
|
|
MP, 1 channel | data | 64 | \q3 &d2 %a2=96 @B0=1 %a98=0 %a4=0 |
|
|
|
|
MP, 2 channel | speech | 112 | \q3 &d2 %a2=96 @B0=2 %a98=2 %a4=1 |
|
|
|
|