16

17.

Press OK.

 

 

 

 

The display shows:

Retry mins: 15

 

 

 

BACK

CHNG

NEXT

18.

Press CHNG.

 

 

 

 

The display shows:

Retry mins:_

 

 

 

CLEAR

BKSP

OK

19.Enter the number of minutes between retries. This must be a number between 1 and 99.

20.Press OK.

The display shows:

Alarm baud: High

 

BACK

CHNG NEXT

21.To change the baud rate, press CHNG until the desired baud rate appears. The baud rate should match that of the alarm device’s modem. You have three choices: Low, Medium and High. The default is High.

IMPORTANT: Changing the baud rate is not required un- less the alarm centre modem is connected to a slow de- vice, such as an old printer. Selecting the Low setting limits the baud rate to less than 300. Selecting the Medium setting limits the baud rate to less than 1200. Selecting the High setting, the baud rate is determined entirely by the FastRAD and the alarm centre modems.

22.Press NEXT.

The display shows:

Parity: None

 

 

BACK

CHNG

NEXT

23.To change the parity setting, press CHNG until the desired setting appears. The parity should match that of the alarm device’s modem. You have three choices: None, Odd and Even. The default is None.

24.Press NEXT.

The display shows:

RAD Admin

 

GEN

ALARM DATA

FastRAD Installation Guide

Page 26
Image 26
Nortel Networks FastRad manual Retry mins