%3.3.7 Lower Base Unit
3.3.7 Lower Base Unit
(1) Remove the upper cover (see 3.3.1).
(2) Remove the connecting cables 4 and 5 of the pulse and main motor from the connectors 2 and 3 of
the Main Control PCB 1.
(3) Remove the screw 9 from the grounding cable and the metal shield. The screw is located directly
above CN1 and the 8-pin DIN connector for the second feeder/multi-purpose feeder.
(4) Remove the connector 6 of the LED head from the Main Control PCB 1.
(5) Remove seven screws 7, then remove the lower base unit 8.
Note:
Use care when lifting the lower base unit. Do not deform the ground clip 10 for the second sheet
feeder.
OKI OL600/610ex (96-01-18