%2. DOS Software Operating PanelOL600e & OL610e - 2.1 Settings Tab
2. DOS Software Operating PanelOL600e & OL610e
• The diagnostic and adjustment controls on the DOS Operating Panel are on the Settings tab, available
to the end user, and the Service tab, available to service personnel only.
• The Operating Panel uses Windows-type controls and displays.
2.1 Settings Tab
• Selected controls on the Settings tab perform adjustment and resetting functions. This tab is avialble to
the end user.
• At the DOS prompt, enter OL600. When the Operator Panel appears, click on Settings or press the ALT
and S keys.
2.1.1. Reset Item
• Click on the item to be reset, then click on Reset.
(1) EEPROM • Resets all EEPROM areas, including Menu level-2, to the factory default values. • The
following items are

not

reset:
Head drive time setting
Fine adjustment of printing start position
Standard tray paper feed amount setting
(2) Menu • Resets all level-1 menu settings to factory fefault values, including all available emulations and
options.
(3) Drum Count • Resets the drum life data. Perform this function whenever the image drum is replaced.
2.1.2. Print Position Adjust