How To Change the Metering Tip:

Remove the chemical feed hose from the barb on the side of the proportioning valve.

Unscrew and remove the old tip.

Screw in the proper tip for your chemical tip and place the hose back on the barb

Proportioning Valve

Turquoise Tip

Dilution 256 - 1

Red Tip

Dilution 85 - 1

Metering Tip Kit – PDE001

Metering Tip Kit (Hydro-Force Item# PDE001) contains 14 different colored metering tips, allowing dilution rates from 11:1 up to 427:1. Refer to the chart below to select the tip that meets the dilution rate for your chemical application.

For example: if you require 1-1/2 ounces of chemical per gallon of water, change to the red metering tip with the dilution rate of 85:1.

The dilution rates are based on chemicals with water-like viscosity. Thicker (more viscous) chemicals will dilute at a different rate.

For powdered chemicals, a liquid concentrate must be made. Mix the concentrate according to the manufacturer’s directions, and then select the appropriate metering tip.

Contact your distributor or Hydro-Force if you have questions about your chemical.

Metering Tip Application Chart:

TIP

CHEMICAL DILUTION RATES

COLOR

OZ / GAL

(RATIO)

 

 

 

 

 

 

TAN

0.30

(427:1)

 

 

 

 

 

ORANGE

0.40

(320:1)

 

TURQUOISE

0.50

(256:1)

 

 

 

 

 

PINK

0.75

(170:1)

 

LIGHT BLUE

1.00

(128:1)

 

BROWN

1.12

(114:1)

 

RED

1.50

(85:1)

 

 

 

 

 

WHITE

1.75

(73:1)

 

GREEN

2.00

(64:1)

 

BLUE

2.50

(51:1)

 

YELLOW

3.75

(34:1)

 

 

 

 

 

BLACK

5.00

(26:1)

 

PURPLE

8.50

(15:1)

 

GRAY

11.50

(11:1)

 

NO TIP

16.25

(8:1)

10