Adjust the length of the chain connecting the float bottle to the float valve.

Water Supply:

Once the correct metering tip is in place:

oConnect the Auto-Fill Water Supply Hose to the water inlet (the male quick-connect on the front of the machine.)

oConnect the other end of the hose to a water faucet, and then turn on the water.

Hot water can be used as long as the temperature does not exceed 180°F.

Faucet adapter kits (Hydro-Force item #AX21 & AX22) are available that allow connection to different types of faucets if needed.

Chemical

Feed Hose

Connect the Auto-Fill Water Supply Hose to Solution Inlet (Male quick connect on the front of the machine.)

3/8” id X 25’ with F Quick Connect & F Garden Hose Fitting

Connect the Auto-Fill Water Supply Hose to a faucet and turn on the water

To adjust the water level in the solution tank:

Turn off the water supply.

Snap the beaded chain off the connector on the valve.

oMove the bottle down to decrease the water level. o Move the bottle up to increase the water level.

Snap the chain back into the connector.

Turn the water supply back on.

If the chemical is not drawing, or if the tank is not filling or is overflowing, refer to the trouble shooting guide, or contact your distributor for assistance.

Chain

Float Valve

Float Bottle

11

Page 11
Image 11
Olympus M1200 manual Water Supply