FLUSH SOLUTION TANK AND PUMP: (continued from previous page)

Direct the end of the prime hose into

the recovery tank vacuum barb

CLEAN PUMP INLET FILTER

Vacuum acid solution out of

Solution Tank

A restricted Pump Inlet Filter can prevent the solution pump from providing adequate pressure for cleaning. A restriction or air leak on the pump inlet can also damage the solution pump check valves and plunger seals.

CAUTION: Before proceeding with this procedure, make sure both power cords are disconnected.

To examine the filter, release the latch on the front of the machine and tilt the tanks off of the base assembly. Support the tanks with a chair, bucket or box while working inside the base.

The filter is in the clear 1/2” ID hose from the solution tank to the inlet port on the solution pump.

Grasp the clear plastic filter cap and unscrew the cap from the black plastic filter body by turning counter-clockwise.

Remove the stainless steel filter screen and clean as needed.

Examine the cap and body for cracks and replace filter as needed. (Replacement Filter: PPU6175)

Check the gasket for nicks or tears and replace filter as needed.

Reassemble filter and check hose clamps and tighten as needed.

Tilt the tanks back onto the base and secure the latch.

Latch

Solution Tank

INLINE FILTER

PPU6175

Base

29

Page 29
Image 29