Omega OMB-DAQBOARD-500 manual Specifications, General, Analog Inputs, of calibration, Input Ranges

Models: OMB-DAQBOARD-500

1 48
Download 48 pages 54.84 Kb
Page 39
Image 39
Specifications

Specifications

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A digital calibration method is used for both analog-to-digital and digital-to-analog

 

 

conversions. Please contact the factory should you believe your board to be in need

 

 

of calibration.

 

 

 

 

 

 

 

General

 

 

 

 

 

 

 

 

 

 

 

 

 

Function:

 

High speed, 16 channel multiplexed 16 Bit Analog-to-Digital converter (ADC)

 

 

with programmable gain, and 24 digital I/O lines for PC compatibles.

 

 

DaqBoard/500 includes two Digital-to-Analog Converters (DAC0 and DAC1)

Board

 

Completely software configurable: Host PC sets all Bus-related selections. All data

Configuration:

 

acquisition-related configuration is done by the user via software.

Analog Inputs

 

 

 

 

 

 

 

 

 

 

 

 

 

Number of

 

16 Single-ended or

 

 

 

 

 

 

 

Inputs:

 

8 Differential programmable on per channel basis

Resolution:

 

155.070 µV/bit on 0 to 10 V range

 

 

 

 

Acquisition

 

 

 

 

 

 

 

 

 

 

 

 

 

Rate:

 

200 kHz max

 

 

 

 

 

 

 

A/D Full Scale

 

 

 

 

 

 

 

 

 

 

 

 

 

Ranges:

 

±10 V; 0 to 10 V

 

 

 

 

 

 

 

Programmable

 

 

 

 

 

 

 

 

 

 

 

 

 

Gain:

 

x1, x2, x4, x8

 

 

 

 

 

 

 

ADC

 

 

 

 

 

 

 

 

 

 

 

 

 

Nonlinearity

 

± 1 LSB

 

 

 

 

 

 

 

 

 

 

(Integral):

 

 

 

 

 

 

 

 

 

 

 

 

 

ADC

 

 

 

 

 

 

 

 

 

 

 

 

 

Nonlinearity

 

± 3 LSB, no missing codes

 

 

 

 

 

 

 

(Differential):

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Ranges

 

 

 

 

Range

 

 

Accuracy*

 

 

Settling

 

 

 

 

 

 

 

 

 

 

 

Time

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Bipolar

 

 

± 10 V

 

± 0.008 V

 

5µs

 

 

 

 

 

± 5 V

 

 

± 0.006 V

 

 

5µs

 

 

 

 

 

 

 

± 2.5 V

 

± 0.004 V

 

20µs

 

 

 

 

 

 

± 1.25V

 

 

± 0.0025V

 

 

20µs

 

 

 

 

Unipolar

 

 

0 to 10 V

 

± 0.006 V

 

5µs

 

 

 

 

 

0 to 5 V

 

 

± 0.004 V

 

 

5µs

 

 

 

 

 

 

 

0 to 2.5 V

 

 

± 0.0025 V

 

 

20µs

 

 

 

 

 

 

 

0 to 1.25 V

 

 

± 0.00125V

 

 

20µs

 

 

*Accuracy 1 year, 18 to 28°C, excluding noise.

Gain Drift:

± 7 ppm/ °C

Zero Drift:

± 2 ppm/ °C

Note: Specifications subject to change without notice.